50GPM Small Flow Fire Pump set

ED small Fire Fighting package set water supply equipment (abbreviated as ED small Fire Fighting package set water supply equipment) refers to the flow less than 100 GPM and A highly integrated mechanical and electrical system consisting of electric centrifugal pump, multi-stage centrifugal pump(pressurized pump group), Diesel Engine Centrifugal pump, pressure limiting protection device(safety valve), valve fittings, control system, pressure sensor system, water-free protection device, backflow preventer, soft joint. bypass pipelines, common base, filters, etc. It is a fire water supply equipment that continuously supplies water to the fire pipe network by preset pressure mode. All accessories of ED small fire fighting package set water supply equipment are assembled according to the standard(NFPA20). Its configuration depends on the needs of customers, or the number of pumps and the type of electric and diesel pump. ED small fire fighting package set water supply equipment is usually equipped with two pumps, one main pump(electric centrifugal pump) and one standby pump(diesel centrifugal pump). The selection of motor and diesel engine depends on the reliability level of the system.

Rated 4.8/5 based on 338 customer reviews
Share:
Previous:
Content

ED small Fire Fighting package set water supply equipment (abbreviated as ED small Fire Fighting package set water supply equipment) refers to the flow less than 100 GPM and A highly integrated mechanical and electrical system consisting of electric centrifugal pump, multi-stage centrifugal pump(pressurized pump group), Diesel Engine Centrifugal pump, pressure limiting protection device(safety valve), valve fittings, control system, pressure sensor system, water-free protection device, backflow preventer, soft joint. bypass pipelines, common base, filters, etc. It is a fire water supply equipment that continuously supplies water to the fire pipe network by preset pressure mode. All accessories of ED small fire fighting package set water supply equipment are assembled according to the standard(NFPA20). Its configuration depends on the needs of customers, or the number of pumps and the type of electric and diesel pump. ED small fire fighting package set water supply equipment is usually equipped with two pumps, one main pump(electric centrifugal pump) and one standby pump(diesel centrifugal pump). The selection of motor and diesel engine depends on the reliability level of the system.

Inquiry


    More Fire Pump Set

    The minimum fire rated pressure of ED small fire fighting package set water supply equipment is 3 bar and the minimum fire rated capacity is 25 GPM. ED small fire fighting package set water supply equipment includes at least two power or power source driven pumping units, pressure tanks, pipes, valves and accessories, measurement and control instruments, control cabinets, outdoor rain cover, etc.
    Motor: Three-phase asynchronous squirrel-cage motor independently developed and manufactured by our company, which can be controlled in production time and greatly shorten the whole set production time.
    Diesel Engine: According to the different parameters of customers, we will choose diesel engines with high cost performance ratio. The main brands are QuanChai, Weichai, ShangChai, FAWDE, Cummins, etc.
    Electric Pumps: Electric pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Diesel Pumps: Diesel pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Electronic Components: The main electric components is CHNT, if Schneider or other brand electrical are need, should mention it before place the order.
    Safety Valve plays a safety protection role in the system. When the system pressure exceeds the prescribed value, the safety valve opens, and a part of the gas/fluid in the system is discharged into the atmosphere/pipeline, so that the system pressure does not exceed the allowable value, so as to ensure that the system does not cause accidents due to excessive pressure.
    Pressure Tank: Water is a non-compressible medium. Generally speaking, the pressure drop of fire-fighting pipe network is normal. However, the pressure drop is very slow, the total loss of water in the pipe network isnot large, and the frequent change of pressure in the pipe network leads to frequent start-up and shutdown of pumps. Especially when the power of equipment is high, it will cause great impact on pressure sensors, relaysand motors, thus affecting the performance and life whole equipment. Therefore, it is necessary to choose the right volume of the pressure tank.

    1. Ability to provide a steady and reliable flow of water: Fire pumps are designed to provide a steady and reliable flow of water to the fire suppression system. This ensures that the fire is extinguished quickly and without any damage to the property.

    2. High-Pressure Output: Fire pumps can provide a high-pressure output to ensure that the water is able to reach further distances and at higher pressures than would be achievable by a standard water system. This is important in controlling and extinguishing fires, as it allows the water to reach all areas of the fire.

    3. Emergency Operation: Fire pumps are designed to be able to operate in the event of a power outage. This ensures that the fire suppression system can still be operational in the event of a power failure. This is especially important in commercial buildings and other areas where power outages can occur.

    4. Automatic Activation: Fire pumps are designed to automatically activate in the event of a fire. This ensures that the fire suppression system can be activated quickly and without any manual intervention. This is especially important in the event of a large fire, as it ensures that the system is already in operation before the fire department arrives.

    5. Low Maintenance: Fire pumps are designed to be low maintenance, requiring only regular inspections and maintenance to ensure that they are working correctly. This ensures that the fire suppression system is always ready for use and that it can be relied upon in the event of a fire.