Complete EDJ fire pump set manufactured according to NFPA20 standard

EDJ series fire pump set consists of electric pump + diesel pump + jockey pump and all accessories.
The pressure switch and the control cabinet can automatically turn on/off the three pumps – the electric pump and the pipe charging pump work when there is electricity, and the diesel pump is started when the power is off.
Flow range: 50-5000 GPM
Pressure range: 4-14 bar
Power range: 4-325 KW

Rated 5/5 based on 258 customer reviews
Share:
Content

Electric pump: end suction pump, split pump, single-stage pump, multi-stage pump. Pump casing material is cast iron or stainless steel Impeller can be copper

Diesel pump: flow head and pressure or other parameters are the same as electric pumps. The diesel engine is connected to the pump set through a highly elastic coupling or a universal joint

Jockey pump: vertical pump type, the technical parameters are different from electric or diesel pumps, and can be customized. It usually has a small flow and a higher lift than an electric or diesel pump

Fire Pump Control Panel: The Fire Pump Control Panel is the brain of the pump system, designed to control and monitor the operation of electric, diesel and jockey pump drives, and compose pumps for manual and automatic models, as well as turn on/off the pump drive under specific conditions.

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.

    Translated with www.DeepL.com/Translator (free version)