Home » Fire Pump Set » ED Fire Pump Systems 30GPM Rapid and Reliable

ED Fire Pump Systems 30GPM Rapid and Reliable

The ED Dual-Power Fire Pump System combines electric and diesel engine pumps to ensure uninterrupted fire protection and a reliable water supply. In the event of power outages or electrical failures, the diesel engine pump seamlessly takes over, guaranteeing continuous operation of the fire protection system. This dual-power configuration offers both reliability and flexibility, providing comprehensive coverage for fire safety needs. With smart controls and automatic switching mechanisms, the transition between electric and diesel engine pumps is seamless, minimizing system downtime. Equipped with advanced safety features, including monitoring and alarm systems, real-time status updates allow for prompt action in case of any irregularities.

Rated 4.8/5 based on 236 customer reviews
Share:
Content

Flow: 30-500GPM

Head: 3-20Bar

Speed: 740-2900r/min

Frequency: 50 HZ or 60 HZ

 

Ensure continuous fire protection with the ED Dual-Power Fire Pump System. Combining the reliability of electric and diesel engine pumps, this innovative system guarantees uninterrupted water supply for enhanced safety in critical fire scenarios.

1.Reliable Performance: The ED Dual-Power Fire Pump System incorporates both an electric pump and a diesel engine pump, providing redundancy for uninterrupted operation. In the event of power outages or electrical failures, the diesel engine pump seamlessly takes over, ensuring a reliable water supply to your fire protection system. Trust in this dual-power setup for dependable performance.

2.Efficiency and Flexibility: The electric pump component of the ED Dual-Power Fire Pump System offers efficient operation under normal conditions, providing optimal pressure for your fire suppression system. Meanwhile, the diesel engine pump ensures reliability when electrical power is compromised. This versatile combination ensures comprehensive fire protection coverage.

3.Seamless Transition: With smart controls and automatic switching mechanisms, the transition between the electric and diesel engine pumps is seamless. This ensures a smooth transfer during power disruptions, minimizing system downtime and maximizing its effectiveness. Count on the ED Dual-Power Fire Pump System for uninterrupted fire protection.

4.Enhanced Safety Features: Equipped with advanced safety features, the ED Dual-Power Fire Pump System includes monitoring and alarm systems for real-time status updates. Prompt action can be taken in case of any irregularities, ensuring a responsive fire protection system. Rest assured that your safety is prioritized.

5.Choose the ED Dual-Power Fire Pump System: Elevate your fire protection capabilities with the reliable ED Dual-Power Fire Pump System. With its dual-power redundancy, efficient operation, and seamless transition between electric and diesel engine pumps, it ensures uninterrupted fire

Inquiry


    More Fire Pump Set

    The minimum fire rated pressure of ED small fire fighting package set water supply equipment is 3 bar and the minimum fire rated capacity is 25 GPM. ED small fire fighting package set water supply equipment includes at least two power or power source driven pumping units, pressure tanks, pipes, valves and accessories, measurement and control instruments, control cabinets, outdoor rain cover, etc.
    Motor: Three-phase asynchronous squirrel-cage motor independently developed and manufactured by our company, which can be controlled in production time and greatly shorten the whole set production time.
    Diesel Engine: According to the different parameters of customers, we will choose diesel engines with high cost performance ratio. The main brands are QuanChai, Weichai, ShangChai, FAWDE, Cummins, etc.
    Electric Pumps: Electric pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Diesel Pumps: Diesel pumps can use vertical in-line pumps, horizontal end-suction pumps, vertical multi-
    stage pumps, horizontal multi-stage pumps, split casing pumps and so on according to the different flow and head of customers.
    Electronic Components: The main electric components is CHNT, if Schneider or other brand electrical are need, should mention it before place the order.
    Safety Valve plays a safety protection role in the system. When the system pressure exceeds the prescribed value, the safety valve opens, and a part of the gas/fluid in the system is discharged into the atmosphere/pipeline, so that the system pressure does not exceed the allowable value, so as to ensure that the system does not cause accidents due to excessive pressure.
    Pressure Tank: Water is a non-compressible medium. Generally speaking, the pressure drop of fire-fighting pipe network is normal. However, the pressure drop is very slow, the total loss of water in the pipe network isnot large, and the frequent change of pressure in the pipe network leads to frequent start-up and shutdown of pumps. Especially when the power of equipment is high, it will cause great impact on pressure sensors, relaysand motors, thus affecting the performance and life whole equipment. Therefore, it is necessary to choose the right volume of the pressure tank.