EDJ Fire Pump Set for Reliable Fire Safety

·UL Standard
Flow:50-3000 GPM
Head: 5-20 Bar (72.5-290 psi)
Speed:740-2900 r/min
·Non-UL Standard
Flow:30-9000 GPM
Head: 3-20 Bar (40-300 psi)
Speed:740-2900 r/min

Rated 4.9/5 based on 578 customer reviews
Share:
Content

The EDJ Fire Pump Set includes diesel engine pumps, electric pumps and jockey pumps.

 

Types of pumps used for fire service include: End Suction Pump,  Split Case Pump, Vertical In-line Pump and Vertical Turbine Pump.

 

1. Electric motor driven pump, can use single stage pump, horizontal split case pump, end suction pump,multistage pump.

2.Diesel engine pump, with capacity and head equal to electric pump, with fuel tank, water tank, fan,control box.

3. Jockey pump, horizontal or vertical, capacity will be small, but head should be higher than electric and diesel engine pump.

4. Control panel: Auto Control of electric pump, diesel engine pump and Jockey Pump with overload, over current protection.

In various fields, our products find applications in large hotels, hospitals, schools,commercial buildings, supermarkets,subway stations, train stations, airports, various transportation tunnels, petrochemical plants, thermal power plants,oil storage tanks, large warehouses, industrial and mining enterprises, seawater injection, etc.

 

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.