EDJ fire pump set occupies a small area

The EDJ fire pump unit is suitable for various fire boosting and pressure stabilizing pump occasions; various villas, residential areas and other fire protection systems; industrial and civil building fire protection systems; suitable for various oil depots, oil loading and unloading docks, logistics parks and other fire protection levels demanding places.

Rated 5/5 based on 471 customer reviews
Share:
Content

The EDJ fire pump unit consists of a fire pump, a double-shaft motor and a diesel engine. One end of the output shaft of the double-shaft motor is connected to the input shaft of the fire pump, and the other end of the output shaft of the double-shaft motor is connected to the One end of a clutch is connected, and the other end of the clutch is connected with the output shaft of the diesel engine. The fire water pump, the double-shaft extension motor, the clutch and the diesel engine are all fixed on the base. The double shaft extension motor, the clutch and the diesel engine are respectively electrically connected with a control circuit through an action drive circuit. With dual-power fire pumps, there is no need to configure a second fire pump, which reduces floor space and saves manufacturing costs.

Inquiry


    More Fire Pump Set

    In the fire fighting pipeline pump, according to the different installation methods can be divided into vertical fire pumps and horizontal fire pumps, many people have questions about these two common pumps, what is the difference between the two? Shanghai Xizhiquan will explain the difference between horizontal and vertical pumps.

    Obviously, different installation methods take up different space. Vertical pipeline pumps are installed vertically, covering a relatively small area, and vertical fire pumps do not require a foundation, while horizontal fire pumps need to be equipped with a base.

    According to the different structures of the two pumps, it can be concluded that there is also a certain difference in the ease of maintenance of the two types of fire fighting pipeline pumps. The impeller of the vertical fire pump needs to be dismantled from top to bottom, which makes maintenance more difficult; the horizontal fire pump only needs to have the inlet pipe removed so that the impeller can be overhauled, which is relatively simple.

    Due to the different inlet and outlet pipe directions, the pipeline connection between vertical and horizontal is also different. As the vertical pump is a bottom-up structure, while the horizontal fire pump is longitudinally arranged on the base, so the motor of the vertical pump and the pump body are connected in the form of sub-mouth connection, while the horizontal pump needs to use couplings to connect with the motor, and the horizontal pipeline pump needs to be corrected regularly.