Home » Other Products » Split Case Centrifugal Fire Pump

Split Case Centrifugal Fire Pump

Applitions:
Water works: Water intake/Water supply/Booster
Industrial use: Water intake/Water supply/Booster/Circulation/
Drainage/Chemical/Re-finery/Firefighting/Sea water desalination
Agricultural use: Irrigation and Drainage

Rated 4.7/5 based on 571 customer reviews
Share:
Content

FEATURES

  1. Split case design permits easy dis-assembly, that is, inspection is simplified, it is not necessary to disturb pump alignment and suction & discharge piping when parts replacement is necessary.
  2. Double suction with advanced design of suction performance ensures high suction lift even with large capacity.
  3. Pump operation with low noise and stability, in use ensure comfortable environment.
  4. Variable combination of materials permit wide application. Drive shaft end of the pump optionally on the left or right.
  5. Shaft seal uncooled soft- packed stuffing box or uncooled single acting unbalanced mechanical seal, etc.
Inquiry


    More Other Products

    Fire pumps are a type of pump used in fire fighting. Compared to ordinary pumps, fire pumps have higher standards and requirements in terms of sealing, corrosion resistance and operational efficiency. Before running the fire pump equipment, we need to discharge the gas inside the pump, do you know what is the significance of doing so? The following is the answer from Shanghai Xizhiquan.

    1. If there is gas inside the fire pump, then the equipment cannot form a sufficient vacuum during operation, resulting in the liquid not being able to be sucked up. This phenomenon is called gas binding, and is a phenomenon that often results from many operators not understanding this operation.
    2, understand the formation of gas binding causes, we will understand how to avoid this problem occurs. Before the fire pump equipment is started, the pump casing needs to be filled with liquid. In the pump suction pipe mouth need to be equipped with a non-return valve, can effectively avoid the pump in the liquid due to gravity into the low tank, if the pump position is low, there is no need to carry out filling the pump.
    3. The compressed gas inside the fire pump will occupy a certain space in the fire pump, making it impossible to seal it.

    Therefore, the operation of deflating the fire pump before putting it into use can increase the vacuum of the equipment and increase the pumping capacity of the pump, thus effectively improving the efficiency of the equipment and reducing the waste of resources.