24 hours Hotline: 0086-570-3010111
Free Call
PRODUCTS
XBD-W horizontal single stage centrifugal fire pump

XBD-W horizontal single stage centrifugal fire pump

Flow:
80.0-2500 gpm / 5-158 l/s
Head:
2-16 bar / 29-232 psi
Caliber:
50-250mm
Power:
3-220kW
Speed:
1500-2600r/min
Working Pressure:
1.6MPa
Share:
Product Overview
Product Structure
Application
Technical Data
Inquiry
Product Overview
 
XBD-W electric fire pump is a kind of new type fire products researched and developed in full compliance with the state issued-newly standard of GB6245-2006 "Fire pump", according to the end-user's practical needs and special using requirements. The inspection of the state fire equipment quality supervising center shows its all kinds of performance indexes are up to or over the standard's requirements and it earned the certificate for fire state products.
Product Structure

1. Pump Body: to lower the velocity of flow, making velocity energy into pressure energy.
2. Impeller: to play a leading role with its vane forcing liquid rotated and splashed around driven by centrifugal force.
3. Pressure Plug: to mount pressure gauge to monitor the normal operation of pump.
4. Air Release Valve: to release the air inside to ensure the normal start of pump.
5. Y/Y2 Series Motor: the driving part of pump, with a close coupled type.
6. Base: pump’s foundation, to ensure the stable of installation.
7. Water Deflector: to avoid water entering motor due to leakage at seal.
8. Pump Cover: elaborately designed of sharing the same end cover with motor, shortened axial dimensions and simple structure.
9. Mechanical Seal: made of stainless steel, tungsten carbide, fluorine rubber and etc, for outstanding sealing, durable service life and leak-tightness.
10. Pump Shaft: coaxial with motor and high concentricity to enable pump operating without noise and vibration.
11. Drain Plug: fully let out the liquid inside in case that pump needs servicing or will be left unused for a long time.

Application
1.Application
XBD electric fire pumps are mainly used for the fixed fire hydrant fire system; automatic spraying fire system used by all sorts of organs, projects, high-floor buildings etc. and can be transferred with the clear water without solid grain under 100 or its equivalence, also be used for public-used water providing system for fire, living, production, construction and municipality.

2. Using Instruction
Before start:
1. Turning the clutch by hand, there should be no jammed phenomenon at the turner position.
2. Opening the inlet valve and the vent valve, letting the water fill into the pump's chamber, then closing the vent valve.
3. Clicking the switch of motor, and confirming whether the turning is right or not.
Running:
1. Fully opening the inlet valves, and closing the valves of the outlet pipe.
2. Connecting the power, Opening the valves of the outlet pipe and adjusting the needed working point when the turning velocity is normal.
3. Watching whether there exist abnormities or not, if yes, should the pump be stopped and inspected before re-running.
Stop:
1. After turning off the outlet valves one by one, shutting off the power.
2. Shutting off the inlet valves.
3. If the ambient temperature is below 0, some warm keeping measures should be adopted.
Technical Data
Model FLow(m3/h)

 

Head(mpa)

 

Power(kw)

 

Speed (rpm)

 

Caliber (mm)

 

XBD2.0/1.1-25W 4 0.2 0.75 2900 25
XBD3.2/1.1-25W 4 0.3 1.5 2900 25
XBD4.0/1.1-32W 4 0.4 2.2 2900 32
XBD5.0/1.25-32W 4.5 0.5 3 2900 32
XBD3.0/1.5-40W 5.4 0.3 2.2 2900 40
XBD8.0/3-40W 10.8 0.8 11 2900 40
XBD3.0/5-50W 18 0.3 4 2900 50
XBD7.0/5-50W 18 0.7 11 2900 50
XBD10.0/5-50W 18 1.0 22 2900 50
XBD12.0/5-50W 18 1.2 30 2900 50
XBD7.0/10-65W 36 0.7 15 2900 65
XBD9.0/15-65W 54 0.9 30 2900 65
XBD10.0/20-80W 72 1.0 55 2900 80
XBD8.0/25-80W 108 0.8 37 2900 80
XBD3.0/25-100W 90 0.3 15 2900 100
XBD4.0/30-100W 108 0.4 18.5 2900 100
XBD5.0/40-100W 144 0.5 37 2900 100
XBD7.0/45-100W 162 0.7 55 2900 100
XBD6.0/45-125W 162 0.6 45 2900 125
XBD12.5/45-125W 194 1.3 90 2900 125
XBD6.0/50-150W 180 0.6 45 2900 150
XBD9.0/50-150W 180 0.9 75 2900 150
XBD4.0/55-150W 198 0.4 37 2900 150
XBD7.0/55-150W 198 0.7 55 2900 150
XBD4.8/55-200W 198 0.5 45 1450 200
XBD3.0/100-200W 360 0.3 55 1450 200
MORE SPECIFICATIONS PLEASE CONTACT US.

 

 

Inquiry
If you have any question or comment, please contact us without hesitation. We will reply you as soon as possible.( * is required information)
* Your email:
* Your name:
* Country:
* Company Name:
Tel:
Contact address:
* Message:
RELATED PRODUCTS
UL Electric Split Case Pump
UL Electric Split Case Pump
Flow:
250-10000 GPM
Head:
3-16 bar
Caliber:
25-500 mm
UL End Suction Pump
UL Listed End Suction Pump
Flow:
50-5000 GPM
Head:
3-16 bar
power:
11-1000 kw
Electric Vertical Turbine Pump
Electric Vertical Turbine Pump
Flow:
50-7500 GPM
Head:
3-20 Bar
Caliber:
50-200 mm
XBD-DL vertical multistage fire pump
XBD-DL vertical multistage fire pump
Flow:
1-200 m³
Head:
30-200m
power:
0.75-200 kw